BOXER Series |
|
|
| |
|
Benefits at a glance:
- Available in PP , PVDF/ECTFE ,ALUMINIUM
, AISI316 STAINLESS STEEL
- Use in potentially-explosive atmospheres
(ATEX zone 1-2 certification)
- Gentle conveyance of liquid
- Ideal for abrasive ,viscous, and shear
sensitive media
Can handle media with entrained solids
- Tolerant of dry running
- No dynamic or pressure loaded seals
- Mobile, easy to transport units
- Infinite regulation of pumping capacity
and of pressure
- Dry self-priming
- Can run against closed valves
- Modern compressed air control, low
main maintenance
- Submersible designs
- Actuated using non-lubricated air
- High tolerance to air with intense
presence of humidity
- Coaxial shaft motor in tolerant synthetic
material
- Pumping capability for both low viscous
and high viscous up to 50.000 cPs
- Twin manifold option ( two suction
and two delivery)
- Bench or ceiling installation
- Three suction and delivery positions
- User-friendly maintenance and parts
replacement
- Excellent performance and value for
money
Description
of the pump
| |
A= Pumping chamber
B= Ball valves
C= Suction manifold
D1= Product –side diaphragm
D2= Air side diaphragm
E=Air control unit
F=Delivery manifold |
 |
| Operation |
| |
ADB
BOXER air operated diaphragm pumps are oscillating
positive displacement pumps with two back to back
pump chambers. These are each divided by a diaphragm
into an air and a fluid area. Both diaphragms are
connected by a common shaft with the effect that
during one pumping stroke medium is pressed out
of the one pump chamber ,while medium is being drawn
into the other pump chamber .
The two adjacent drawings describe the sequence
of a complete cycle consisting of a suction and
pressure strokes of an air operated diaphragm pump.
In the drawings the medium is colored in blue while
the air in red. |
| |
|
|
STEP 1 |
| |
By filling
the left hand air chamber with air (red) the left
hand diaphragm is pushed outwards. This pulls the
inner cap on the right hand diaphragm to the initial
position carrying the diaphragm along. The valve
ball (1) is drawn out of it’s position the medium
(blue) flows into the right hand pump chamber. At
the same time valve ball (2) is seated in a closed
position by the vacuum. The right hand pump chamber
fills up with medium (blue) |
|
| |
|
|
| STEP
2 |
| |
The control
valve (3) switches over the air flow into the right
hand air chamber (red). The left hand air chamber
is exhausted. The suction process (see step 1) now
takes place in the left hand pump chamber. Medium
(blue) is pressed out of the right hand pump chamber
, valve ball (1) is pressed down and closes while
valve ball (2) opens allowing the medium to flow
to the outlet. |
|
|
|
|
| |