ADB BOXER Series
 


Benefits at a glance:

  • Available in PP , PVDF/ECTFE ,ALUMINIUM , AISI316 STAINLESS STEEL
  • Use in potentially-explosive atmospheres (ATEX zone 1-2 certification)
  • Gentle conveyance of liquid
  • Ideal for abrasive ,viscous, and shear sensitive media
  • Can handle media with entrained solids
  • Tolerant of dry running
  • No dynamic or pressure loaded seals
  • Mobile, easy to transport units
  • Infinite regulation of pumping capacity and of pressure
  • Dry self-priming
  • Can run against closed valves
  • Modern compressed air control, low main maintenance
  • Submersible designs
  • Actuated using non-lubricated air
  • High tolerance to air with intense presence of humidity
  • Coaxial shaft motor in tolerant synthetic material
  • Pumping capability for both low viscous and high viscous up to 50.000 cPs
  • Twin manifold option ( two suction and two delivery)
  • Bench or ceiling installation
  • Three suction and delivery positions
  • User-friendly maintenance and parts replacement
  • Excellent performance and value for money

 

Description of the pump

  A= Pumping chamber
B= Ball valves
C= Suction manifold
D1= Product –side diaphragm
D2= Air side diaphragm
E=Air control unit
F=Delivery manifold

 

Operation
 
ADB BOXER air operated diaphragm pumps are oscillating positive displacement pumps with two back to back pump chambers. These are each divided by a diaphragm into an air and a fluid area. Both diaphragms are connected by a common shaft with the effect that during one pumping stroke medium is pressed out of the one pump chamber ,while medium is being drawn into the other pump chamber .
The two adjacent drawings describe the sequence of a complete cycle consisting of a suction and pressure strokes of an air operated diaphragm pump.
In the drawings the medium is colored in blue while the air in red.
     

STEP 1
 
By filling the left hand air chamber with air (red) the left hand diaphragm is pushed outwards. This pulls the inner cap on the right hand diaphragm to the initial position carrying the diaphragm along. The valve ball (1) is drawn out of it’s position the medium (blue) flows into the right hand pump chamber. At the same time valve ball (2) is seated in a closed position by the vacuum. The right hand pump chamber fills up with medium (blue)
     
STEP 2
 
The control valve (3) switches over the air flow into the right hand air chamber (red). The left hand air chamber is exhausted. The suction process (see step 1) now takes place in the left hand pump chamber. Medium (blue) is pressed out of the right hand pump chamber , valve ball (1) is pressed down and closes while valve ball (2) opens allowing the medium to flow to the outlet.
 
 
36 Methonis st, Piraeus, Post code: 185 45
Tel: (+30) 210.4200422, (+30) 210.4200338 - 9, Fax: (+30) 210.4200423,
info@boxerpump.com

 